Show simple item record

dc.contributor.authorSahu, Aditi
dc.contributor.authorYélamos, Oriol
dc.contributor.authorIftimia, Nicusor
dc.contributor.authorCordova, Miguel
dc.contributor.authorAlessi-Fox, Christi
dc.contributor.authorGill, Melissa
dc.contributor.authorMaguluri, Gopi
dc.contributor.authorDusza, Stephen W
dc.contributor.authorNavarrete-Dechent, Cristián
dc.contributor.authorGonzález, Salvador
dc.contributor.authorRossi, Anthony M
dc.contributor.authorMarghoob, Ashfaq A
dc.contributor.authorRajadhyaksha, Milind
dc.contributor.authorChen, Chih-Shan J
dc.date.accessioned2022-11-02T17:10:20Z
dc.date.available2022-11-02T17:10:20Z
dc.identifier.citationSahu A, Yélamos O, Iftimia N, Cordova M, Alessi-Fox C, Gill M, Maguluri G, Dusza SW, Navarrete-Dechent C, González S, Rossi AM, Marghoob AA, Rajadhyaksha M, Chen CJ. Evaluation of a Combined Reflectance Confocal Microscopy-Optical Coherence Tomography Device for Detection and Depth Assessment of Basal Cell Carcinoma. JAMA Dermatol. 2018 Oct 1;154(10):1175-1183. doi: 10.1001/jamadermatol.2018.2446. PMID: 30140851; PMCID: PMC6179925.en_US
dc.identifier.eissn2168-6084
dc.identifier.doi10.1001/jamadermatol.2018.2446
dc.identifier.pmid30140851
dc.identifier.urihttp://hdl.handle.net/20.500.12648/7842
dc.description.abstractImportance: The limited tissue sampling of a biopsy can lead to an incomplete assessment of basal cell carcinoma (BCC) subtypes and depth. Reflectance confocal microscopy (RCM) combined with optical coherence tomography (OCT) imaging may enable real-time, noninvasive, comprehensive three-dimensional sampling in vivo, which may improve the diagnostic accuracy and margin assessment of BCCs. Objective: To determine the accuracy of a combined RCM-OCT device for BCC detection and deep margin assessment. Design, setting, and participants: This pilot study was carried out on 85 lesions from 55 patients referred for physician consultation or Mohs surgery at Memorial Sloan Kettering Skin Cancer Center in Hauppauge, New York. These patients were prospectively and consecutively enrolled in the study between January 1, 2017, and December 31, 2017. Patients underwent imaging, with the combined RCM-OCT probe, for previously biopsied, histopathologically confirmed BCCs and lesions clinically or dermoscopically suggestive of BCC. Only patients with available histopathologic examination after imaging were included. Main outcomes and measures: Improvements in sensitivity, specificity, and diagnostic accuracy for BCC using the combined RCM-OCT probe as well as the correlation between OCT-estimated depth and histopathologically measured depth were investigated. Results: In total, 85 lesions from 55 patients (27 [49%] were female and 28 [51%] were male with a median [range] age of 59 [21-90] years) were imaged. Imaging was performed on 25 previously biopsied and histopathologically confirmed BCCs and 60 previously nonbiopsied but clinically or dermoscopically suspicious lesions. Normal skin and BCC features were correlated and validated with histopathologic examination. In previously biopsied lesions, residual tumors were detected in 12 of 25 (48%) lesions with 100% sensitivity (95% CI, 73.5%-100%) and 23.1% specificity (95% CI, 5.0%-53.8%) for combined RCM-OCT probe. In previously nonbiopsied and suspicious lesions, BCCs were diagnosed in 48 of 60 (80%) lesions with 100% sensitivity (95% CI, 92.6%-100%) and 75% specificity (95% CI, 42.8%-94.5%). Correlation was observed between depth estimated with OCT and depth measured with histopathologic examination: the coefficient of determination (R2) was 0.75 (R = 0.86; P < .001) for all lesions, 0.73 (R = 0.85; P < .001) for lesions less than 500 μm deep, and 0.65 (R = 0.43; P < .001) for lesions greater than 500 μm deep. Conclusions and relevance: Combined RCM-OCT imaging may be prospectively used to comprehensively diagnose lesions suggestive of BCC and triage for treatment. Further validation of this device must be performed on a larger cohort.en_US
dc.language.isoenen_US
dc.relation.urlhttps://jamanetwork.com/journals/jamadermatology/fullarticle/2697217en_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleEvaluation of a Combined Reflectance Confocal Microscopy-Optical Coherence Tomography Device for Detection and Depth Assessment of Basal Cell Carcinoma.en_US
dc.typeArticle/Reviewen_US
dc.source.journaltitleJAMA dermatologyen_US
dc.source.volume154
dc.source.issue10
dc.source.beginpage1175
dc.source.endpage1183
dc.source.countryUnited States
dc.source.countryUnited States
dc.source.countryUnited States
dc.description.versionVoRen_US
refterms.dateFOA2022-11-02T17:10:21Z
dc.description.institutionSUNY Downstateen_US
dc.description.departmentPathologyen_US
dc.description.degreelevelN/Aen_US
dc.identifier.journalJAMA dermatology


Files in this item

Thumbnail
Name:
jamadermatology_sahu_2018_oi_1 ...
Size:
4.627Mb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 International
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 International