Show simple item record

dc.contributor.authorOrtega, Francis A.
dc.contributor.authorGrandi, Eleonora
dc.contributor.authorKrogh-Madsen, Trine
dc.contributor.authorChristini, David J.
dc.date.accessioned2024-11-20T19:40:17Z
dc.date.available2024-11-20T19:40:17Z
dc.date.issued2018-01-04
dc.identifier.citationOrtega FA, Grandi E, Krogh-Madsen T, Christini DJ. Applications of Dynamic Clamp to Cardiac Arrhythmia Research: Role in Drug Target Discovery and Safety Pharmacology Testing. Front Physiol. 2018 Jan 4;8:1099. doi: 10.3389/fphys.2017.01099. PMID: 29354069; PMCID: PMC5758594.en_US
dc.identifier.eissn1664-042X
dc.identifier.doi10.3389/fphys.2017.01099
dc.identifier.pmid29354069
dc.identifier.pii10.3389/fphys.2017.01099
dc.identifier.urihttp://hdl.handle.net/20.500.12648/15851
dc.description.abstractDynamic clamp, a hybrid-computational-experimental technique that has been used to elucidate ionic mechanisms underlying cardiac electrophysiology, is emerging as a promising tool in the discovery of potential anti-arrhythmic targets and in pharmacological safety testing. Through the injection of computationally simulated conductances into isolated cardiomyocytes in a real-time continuous loop, dynamic clamp has greatly expanded the capabilities of patch clamp outside traditional static voltage and current protocols. Recent applications include fine manipulation of injected artificial conductances to identify promising drug targets in the prevention of arrhythmia and the direct testing of model-based hypotheses. Furthermore, dynamic clamp has been used to enhance existing experimental models by addressing their intrinsic limitations, which increased predictive power in identifying pro-arrhythmic pharmacological compounds. Here, we review the recent advances of the dynamic clamp technique in cardiac electrophysiology with a focus on its future role in the development of safety testing and discovery of anti-arrhythmic drugs.en_US
dc.description.sponsorshipNational Institutes of Healthen_US
dc.language.isoN/Aen_US
dc.publisherFrontiers Media SAen_US
dc.relation.urlhttps://www.frontiersin.org/journals/physiology/articles/10.3389/fphys.2017.01099/fullen_US
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectantiarrhythmic drugsen_US
dc.subjectarrhythmia mechanismsen_US
dc.subjectcardiac electrophysiologyen_US
dc.subjectcardiac modelingen_US
dc.subjectdynamic clampen_US
dc.subjectpharmacology & drug discoveryen_US
dc.titleApplications of Dynamic Clamp to Cardiac Arrhythmia Research: Role in Drug Target Discovery and Safety Pharmacology Testingen_US
dc.typeArticle/Reviewen_US
dc.source.journaltitleFrontiers in Physiologyen_US
dc.source.volume8
dc.description.versionVoRen_US
refterms.dateFOA2024-11-20T19:40:18Z
dc.description.institutionSUNY Downstateen_US
dc.description.departmentPhysiology and Pharmacologyen_US
dc.description.degreelevelN/Aen_US


Files in this item

Thumbnail
Name:
fphys-08-01099.pdf
Size:
1.194Mb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record

https://creativecommons.org/licenses/by/4.0/
Except where otherwise noted, this item's license is described as https://creativecommons.org/licenses/by/4.0/